上海麒诺 QN TECHNOLOGY
SCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin - Flow Sensors for Laboratory, Pharmaceutical and Clean Room Technology
Duplex-Laminar-Flow Sensor SS 20.415 Twin

SCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin - Flow Sensors for Laboratory, Pharmaceutical and Clean Room Technology

SCHMIDT TechnologyLead Time on InquiryOrigin 德国

SCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin - Flow Sensors for Laboratory, Pharmaceutical and Clean Room Technology. Measuring quantity Standard flow velocity

Product Overview

The SCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin is part of the SCHMIDT Flow Sensors for Laboratory, Pharmaceutical and Clean Room Technology line. Doubled validation of laminar flow(registered design) Thermal duplex flow sensor for redundant validation of laminar flow applications at one measuring point. Redundant validation of laminar flow applicationsTwo independent, full-fledged flow sensors in one unitEasy installation at one measuring pointNo mutual influence of measurementsConfined space becomes a minor matter'Plug and Play' combined with quick assemblyPrecise measurement of low flow velocity [... We supply genuine, brand-new SCHMIDT Technology products with selection support, technical documentation and stable supply.

Specifications

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1)技术参数
被测介质 / Measured mediumClean air or nitrogen, additional gases on request技术参数
量程 / Measuring range wN0 ... 1 / 2.5 m/s技术参数
显示 / Max. display range wN+10 % above measuring range技术参数
最低检出限 / Lower detection limit wN0.05 m/s技术参数
测量精度(标准) / Standard wN±(3 % of measured value + 0.05 m/s) 2)测量精度
测量精度(高精度可选) / High precision (optional) wN±(1 % of measured value + 0.04 m/s) 2)测量精度
响应时间 / Response time (t90) wN5 s测量精度
Sensor0 ... +60 °C工作温度
存储温度 / Storage temperature-20 ... +85 °C工作温度
传感器头部 / Sensor headStainless steel 1.4404材质
传感器管 / Sensor tubeStainless steel 1.4404材质
Plug connector, nut srewStainless steel 1.4404材质
光环 / Light ringPC材质
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH)通用参数
工作压力 / Operating pressure (max.)Atmospheric (700 ... 1,300 hPa)通用参数
供电电压 / Supply voltage24 V DC ± 10 %通用参数
电流消耗 / Current consumptionTyp. 32 mA / max. 45 mA (including all signal output currents)通用参数
模拟输出 / Analog outputs wN,A & wN,B0 ... 10 V (RL >= 10 kohm; short-circuit protected) | 4 ... 20 mA (RL <= 300 ohm>br> CL <= 10 nF通用参数
故障信号 / Error signalOnly with current interface: 2 mA (according to NAMUR NE43)通用参数
电气连接 / Electrical connectionPlug-in-connector M9, male, 7-pin (shielded), screwed通用参数
最大电缆长度 / Maximum cable lengthVoltage interface: 10 m | Current interface: 100 m通用参数
安装位置 / Mounting positionStraight: ±3° relative to flow direction | Angled: Vertical downdraft flow (per design)通用参数
防护等级 / Protection typeSensor: IP65; electrical connector: IP67 (with correctly attached cable)通用参数
防护等级 / Protection classIII (SELV or PELV)通用参数
Sensor lengthAngled: 150/270 mm (vertical) x 300 mm (horizontal) | Straight: 300 mm通用参数
重量 / WeightApprox. 250 g (angled design with 270 mm x 300 mm)通用参数

Need a quotation and lead time for this product?

Just share the model — we will reply with genuine-channel information, pricing and lead time within 24 hours.