上海麒诺 QN TECHNOLOGY
SCHMIDT® Flow Sensor SS 20.600 - Flow Sensors and Accessories
Flow Sensor SS 20.600

SCHMIDT® Flow Sensor SS 20.600 - Flow Sensors and Accessories

SCHMIDT TechnologyLead Time on InquiryOrigin 德国

SCHMIDT® Flow Sensor SS 20.600 - Flow Sensors and Accessories. Measuring quantity Standard flow velocity wN based on standard conditions 1) | Temperature of medium T

Product Overview

The SCHMIDT® Flow Sensor SS 20.600 is part of the SCHMIDT Flow Sensors and Accessories line. Flow rates of gases - an important measurement in industrial processes. Chamber head (fast response time)Flow and temperature signalProbe length 120 ... 1,000 mm (optional special length)Remote sensor (optional)Measuring ranges 0 ... We supply genuine, brand-new SCHMIDT Technology products with selection support, technical documentation and stable supply.

Specifications

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1) | Temperature of medium TM技术参数
被测介质 / Measured mediumAir or nitrogen | Optional: Natural gas, biogas, CO2, special gases and gas mixtures技术参数
量程 / Measuring range wN0 ... 10 / 20 / 60 / 90 / 140 / 220 m/s | Optional: Customised measuring ranges in 0.1 m/s steps技术参数
最低检出限 / Lower detection limit wN0.2 m/s技术参数
介质温度量程 / Measuring range TMSS 20.600: -20 ... +120 °C | SS 20.600 Ex: -40 ... +120 °C技术参数
测量精度(标准) / Standard wN±(3 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)测量精度
测量精度(高精度可选) / High precision wN | (optional for air, nitrogen, oxygen only)±(1 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)测量精度
响应时间 / Response time (t90) wN1 s (jump of wN from 0 to 5 m/s in air)测量精度
温度梯度 / Temperature gradient wN< 8 K/min (at wN = 5 m/s in air)测量精度
TM (wN > 2 m/s)±1 K (10 ... 30 °C); ±2 K (remaining measuring range)测量精度
SensorStandard/oxygen: -20 ... +120 °C | ATEX: -40 ... +120 °C工作温度
Electronics-20 ... +70 °C工作温度
存储温度 / Storage temperature-20 ... +85 °C工作温度
外壳 / EnclosureAluminium, anodised材质
传感器管 / Sensor tube, compression fittingStainless steel 1.4571材质
传感器头部 / Sensor headPlatinum element (glass passivated); PPO/PA材质
Protective sleeve (ATEX option)Aluminium, anodised材质
传感器电缆 / Sensor cable (of remote sensor)Jacket (PUR, halogen free, UL)材质
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH)通用参数
工作压力 / Operating pressure (max.)Standard: 16 bar; option: 40 bar; oxygen (O2 > 21 %): 20 bar通用参数
显示 / Display4 x Duo-LEDs (green/red/orange)通用参数
供电电压 / Supply voltage24 V DC ± 20 %通用参数
电流消耗 / Current consumptionTyp. 80 mA (without pulse outputs); max. 250 mA (including signal currents of all outputs)通用参数
模拟输出 / Analog outputs | Type: Auto U / I)wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF通用参数
脉冲输出:信号形式 / Pulse outputs: SignalizationStandard: Frequency f ~ wN | f = 0 ... fmax | fmax = 100 Hz (option: fmax = 10 ... 99 Hz) | Optional: Pulse quantity: | 1 pulse/1 m3; 1 pulse/0.1 m3; 1 pulse/0.01 m3 (max. 100 pulses/s)通用参数
脉冲输出:技术 / Pulse outputs: Technology1. Highside-driver (PNP, open collector) at protected supply voltage; not galvanically isolated) | Short-circuit protected (analog): 100 mA | High level: > supply voltage - 3 V | Leckage current: IOFF < 10 µA | 2. Semiconductor relay; output galvanically isolated | Output voltage/current: Max. 30 V / 50 mA通用参数
电气连接 / Electrical connectionPlug-in connector M12 (A-coded), male, 8-pin (shielded), screwed | ATEX approval only in combination with original cable!通用参数
最大电缆长度 / Maximum cable lengthVoltage interface / current interface / pulse outputs: 100 m | Voltage mode: Use AGND and RL >= 10 k (mass offset)通用参数
安装位置 / Mounting positionArbitrary (with vertical downdraft: lower detection limit = 2 m/s at 16 bar)通用参数
安装公差 / Mounting tolerance±3° relative to flow direction (unidirectional)通用参数
最小插入深度 / Minimum immersion depthDN25通用参数
防护等级 / Protection typeSensor probe: IP67; enclosure: IP65; electrical connector: IP67 (with correctly attached cable)通用参数
防护等级 / Protection classIII (SELV or PELV)通用参数
ATEX categoryGas (zone 2): II 3G Ex ec ic IIC T4 Gc | Dust (zone 22): II 3D Ex ic tc IIIC T135°C Dc通用参数
探头长度 / Probe lengthCompact version: 120/250/400/600 mm; special lengths from 120 to 1,000 mm (step: 10 mm) | Remote version: Probe 120/250/400/600 mm; Remote cable: 1 ... 10 m (step: 1 m)通用参数
重量 / WeightApprox. 500 g max. (without connection cable)通用参数

Need a quotation and lead time for this product?

Just share the model — we will reply with genuine-channel information, pricing and lead time within 24 hours.