上海麒诺 QN TECHNOLOGY
SCHMIDT® Flow Sensor SS 23.700 Ex Biogas 流量传感器
Flow Sensor SS 23.700 Ex Biogas

SCHMIDT® Flow Sensor SS 23.700 Ex Biogas 流量传感器

SCHMIDT Technology询货期产地 德国

SCHMIDT® Flow Sensor SS 23.700 Ex Biogas 流量传感器,量程 0 ... 10 / 20 / 60 / 90 / 140 / 220 m/s | Optional: Customised measuri

产品概述

SCHMIDT® Flow Sensor SS 23.700 Ex Biogas 属于 SCHMIDT 污水处理与沼气用流量传感器(Flow Sensors for Sewage Treatment Plants and Biogas)产品线,量程 0 ... 10 / 20 / 60 / 90 / 140 / 220 m/s | Optional: Customised measuring ranges in steps of 1 m/s;介质温度量程 -20 ... +120 °C;供电电压 24 V DC ± 20 %;模拟输出 wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF。我司经销 SCHMIDT Technology 原装全新正品,可提供选型支持、技术资料与稳定供货。

技术参数

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1) | Temperature of medium TM技术参数
被测介质 / Measured mediumBiogas, optional: methane, natural gas, ; special gases and mixtures and others (on request)技术参数
量程 / Measuring range wN0 ... 10 / 20 / 60 / 90 / 140 / 220 m/s | Optional: Customised measuring ranges in steps of 1 m/s技术参数
最低检出限 / Lower detection limit wN0.1 m/s技术参数
介质温度量程 / Measuring range TM-20 ... +120 °C技术参数
测量精度(标准) / Standard wN±(3 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)测量精度
响应时间 / Response time (t90) wN10 s (jump of wN from 0 to 5 m/s in air)测量精度
TM (wN > 2 m/s)±1 K (10 ... 30 °C); ±2 K (remaining measuring range)测量精度
传感器探头 / Sensor probe-20 ... +120 °C工作温度
Electronics-20 ... +70 °C工作温度
存储温度 / Storage temperature-20 ... +85 °C工作温度
外壳 / HousingAluminium, anodised材质
传感器管 / Sensor tubeStainless steel 1.4571材质
传感器头部 / Sensor headStainless steel 1.4404材质
传感器电缆 / Sensor cable (of remote sensor)Jacket TPE, halogen-free材质
卡套接头 / Compression fittingStandard: Stainless steel 1.4571, FKM | PWIS-compliant: Stainless steel 1.4571, coating DurniCoat (NiP)材质
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH)通用参数
工作压力 / Operating pressure (max.)16 bar通用参数
显示 / Display4 x Duo-LEDs (green/red/orange)通用参数
供电电压 / Supply voltage24 V DC ± 20 %通用参数
电流消耗 / Current consumptionTyp. 80 mA (without pulse outputs); max. 250 mA (excluding signal current of pulse output 2 [relay])通用参数
模拟输出 / Analog outputs | Type: Auto U / I)wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF通用参数
脉冲输出:信号形式 / Pulse outputs: SignalizationFrequency: wN ~ f = 0 ... fmax; fmax = 10 ... 100 Hz | Optional: 1 pulse/1 m3; 1 pulse/0.1 m3; 1 pulse/0.01 m3 (max. 100 pulses/s)通用参数
脉冲输出:技术 / Pulse outputs: Technology1. Highside-driver (PNP, open collector) at protected supply voltage; not galvanically isolated) | Short-circuit protected (analog): 100 mA | High level: > supply voltage - 3 V | Leckage current: IOFF < 10 µA | 2. Semiconductor relay; output galvanically isolated | Output voltage/current: Max. 30 V / 50 mA通用参数
电气连接 / Electrical connectionPlug-in connector M12 (A-coded), male, 8-pin (shielded), screwed通用参数
最大电缆长度 / Maximum cable lengthVoltage interface / current interface / pulse outputs: 100 m | Voltage mode: Use AGND and RL >= 10 k (mass offset)通用参数
安装位置 / Mounting positionArbitrary (exception: Temperature element may never be placed "above" heater element)通用参数
安装公差 / Mounting tolerance±3° relative to flow direction (unidirectional)通用参数
最小插入深度 / Minimum immersion depthDN40通用参数
防护等级 / Protection typeSensor probe: IP67; enclosure: IP65 (with correctly attached cable)通用参数
防护等级 / Protection classIII (PELV)通用参数
ATEX-DeclarationGas (zone 2): II 3G Ex ec ic IIC T4 Gc | Dust (zone 22): II 3D Ex ic tc T135°C Dc通用参数
探头长度 / Probe lengthCompact version: 250/600 mm | Remote version: Probe 250/600 mm; cable: 1 ... 10 m (steps: 1 m)通用参数
重量 / WeightApprox. 500 g max. (without connection cable)通用参数

需要这款产品的报价与货期?