SCHMIDT® Flow Sensor SS 20.651 流量传感器,量程 0 ... 10 / 20 / 40 / 60 m/s;介质温度量程 0 ... +200/+350 °C;供电电压 24 V DC ± 20 %,原装全新正品

产品概述

SCHMIDT® Flow Sensor SS 20.651 属于 SCHMIDT 燃烧器与工业炉用流量传感器(Flow Sensors for Burners and Furnace Construction)产品线,量程 0 ... 10 / 20 / 40 / 60 m/s;介质温度量程 0 ... +200/+350 °C;供电电压 24 V DC ± 20 %;模拟输出 wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF。我司经销 SCHMIDT Technology 原装全新正品,可提供选型支持、技术资料与稳定供货。

技术参数

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1) | Medium temperature TM技术参数
被测介质 / Measured mediumClean air or nitrogen, other gases upon request技术参数
量程 / Measuring range wN0 ... 10 / 20 / 40 / 60 m/s技术参数
最低检出限 / Lower detection limit wN0.2 m/s (at TM = 20 °C)技术参数
介质温度量程 / Measuring range TM0 ... +200/+350 °C技术参数
传感器头部 / Sensor head0 ... +200/+350 °C工作温度
Electronics-20 ... +70 °C工作温度
存储温度 / Storage temperature-20 ... +85 °C工作温度
外壳 / HousingAluminium, anodised材质
传感器管 / Sensor tubeStainless steel 1.4571材质
传感器头部 / Sensor headPlatinum element (glass-passivated), ceramics材质
卡套接头 / Compression fittingStainless steel 1.4571 or brass (depending on sensor option)材质
测量精度(标准) / Standard wN±(3 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)测量精度
测量精度(高精度可选) / High precision (optional) wN±(1 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2)测量精度
响应时间 / Response time (t90) wN3 s (jump of wN from 0 to 5 m/s in air)测量精度
温度梯度 / Temperature gradient wN< 8 K/min (at wN = 5 m/s in air)测量精度
Temperature TM (wN > 2 m/s)±2 K (TM = 10 ... 30 °C); ±4 K (remaining measuring range)测量精度
Recovery time wN< 10 s (after temperature change of ∆ϑ = 40 K and at wN = 5 m/s in air)测量精度
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH); high relative air humidity in combination with high temperature can cause measurement deviations通用参数
工作压力 / Operating pressure (max.)Atmospheric (700 ... 1,300 hPa) / 16 bar (optional; over pressure)通用参数
显示 / Display4 x Duo-LEDs (green/red/orange)通用参数
供电电压 / Supply voltage24 V DC ± 20 %通用参数
电流消耗 / Current consumptionTyp. 50 mA (without pulse outputs); max. 250 mA (including signal currents of all outputs)通用参数
Start up timeApprox. 10 s after switch-on通用参数
模拟输出 / Analog outputs | Type: Auto U / I)wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF通用参数
脉冲输出:信号形式 / Pulse outputs: SignalizationStandard: Frequency f ~ wN | f = 0 ... fmax | fmax = 100 Hz (option: fmax = 10 ... 99 Hz) | Optional: Pulse quantity: | 1 pulse/1 m3; 1 pulse/0.1 m3; 1 pulse/0.01 m3 (max. 100 pulses/s)通用参数
脉冲输出:技术 / Pulse outputs: Technology1. Highside-driver (PNP, open collector) at protected supply voltage; not galvanically isolated) | Short-circuit protected (analog): 100 mA | High level: > supply voltage - 3 V | Leckage current: IOFF < 10 µA | 2. Semiconductor relay; output galvanically isolated | Output voltage/current: Max. 30 V / 50 mA通用参数
Fieldbus (optional)Profibus DP / DeviceNet通用参数
电气连接 / Electrical connectionPlug-in connector M12 (A-coded), male, 8-pole (shielded), screwed通用参数
最大电缆长度 / Maximum cable lengthVoltage interface / current interface / pulse outputs: 100 m | Voltage mode: Use AGND and RL >= 10 k (mass offset)通用参数
安装位置 / Mounting positionArbitrary (atmospheric; under higher pressure preferred horizontally)通用参数
安装公差 / Mounting tolerance±3° relative to flow direction (unidirectional)通用参数
最小插入深度 / Minimum immersion depthDN25 ( also more, depending on the temperature of medium)通用参数
Power-up time10 s (after switching-on)通用参数
防护等级 / Protection typeSensor probe: IP54; enclosure: IP65; electrical connector: IP67 (with correctly attached cable)通用参数
防护等级 / Protection classIII (SELV or PELV)通用参数
探头长度 / Probe length250/400/600/1,000 mm (for both versions: compact and remote probe)通用参数
Cable length (remote version)Selectable: 1 ... 10 m (step: 1 m)通用参数
重量 / Weight550 g max. (400 mm probe length) / 750 g (field bus version)通用参数