上海麒诺 QN TECHNOLOGY
SCHMIDT® Flow Sensor SS 20.260 流量传感器
Flow Sensor SS 20.260

SCHMIDT® Flow Sensor SS 20.260 流量传感器

SCHMIDT Technology询货期产地 德国

SCHMIDT® Flow Sensor SS 20.260 流量传感器,量程 0 ... 2.5 / 10 / 20 / 40 / 50 / 60 m/s;介质温度量程 -20 ... +120 °C;供电电压 24 V DC ± 10

产品概述

SCHMIDT® Flow Sensor SS 20.260 属于 SCHMIDT 流量传感器与附件(Flow Sensors and Accessories)产品线,量程 0 ... 2.5 / 10 / 20 / 40 / 50 / 60 m/s;介质温度量程 -20 ... +120 °C;供电电压 24 V DC ± 10 %;测量精度(标准) ±(5 % of measured value + [0.4 % of fmr; min. 0.02 m/s]) 2)。我司经销 SCHMIDT Technology 原装全新正品,可提供选型支持、技术资料与稳定供货。

技术参数

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1) | Temperature of medium TM (optional)技术参数
被测介质 / Measured mediumAir or nitrogen, other gases upon request技术参数
量程 / Measuring range wN0 ... 2.5 / 10 / 20 / 40 / 50 / 60 m/s技术参数
最低检出限 / Lower detection limit wN0.2 m/s技术参数
介质温度量程 / Measuring range TM (optional)-20 ... +120 °C技术参数
测量精度(标准) / Standard wN±(5 % of measured value + [0.4 % of fmr; min. 0.02 m/s]) 2)测量精度
测量精度(高精度可选) / High precision (optional) wN±(3 % of measured value + [0.4 % of fmr; min. 0.02 m/s]) 2)测量精度
响应时间 / Response time (t90) wN3 s (jump from 0 to 5 m/s)测量精度
温度梯度 / Temperature gradient wN< 8 K/min (at wN = 5 m/s in air)测量精度
TM (wN > 2 m/s)±1 K (0 ... 40 °C); ±2 K (remaining measuring range)测量精度
传感器探头 / Sensor probe-20 ... +120 °C工作温度
Electronics-20 ... +70 °C工作温度
存储温度 / Storage temperature-20 ... +85 °C工作温度
传感器头部 / Sensor headPlatinum element (glass passivated); PPO/PA材质
传感器管 / Sensor tubeStainless steel 1.4571材质
外壳 / EnclosurePBT (glass-fibre reinforced)材质
传感器电缆 / Sensor cablePVC材质
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH)通用参数
工作压力 / Operating pressure (max.)Atmospheric (700 ... 1,300 hPa)通用参数
显示 / DisplayLED green: Operating status | LED red (flashing): Sensor defective通用参数
供电电压 / Supply voltage24 V DC ± 10 %通用参数
电流消耗 / Current consumption< 60 mA通用参数
Analog outputShort circuit protected; load capacity CL <= 10 nF通用参数
- Standard: wN1 x 0 ... 10 V (RL >= 10 kohm) or 4 ... 20 mA (RL <= 300 ohm)通用参数
- Option: wN and TM2 x 4 ... 20 mA (RL <= 300 ohm)通用参数
电气连接 / Electrical connectionNon-detachable cable, 4 x 0.14 mm2, with ferrules: | - Standard: Length 2 m | - 0.2 m length with M12 connector (male, A-coded, 4-pole, screwed) | - Special length: 3 ... 100 m (step: 1 m)通用参数
最大电缆长度 / Maximum cable length100 m | Variant without TM-output: Tension mode using AGND and RL >= 10 kohm (minimizing mass offset)通用参数
安装位置 / Mounting positionArbitrary通用参数
安装公差 / Mounting tolerance±3° relative to flow direction (unidirectional)通用参数
防护等级 / Protection typeSensor probe: IP65; enclosure: IP64; plug-in connection: IP67 (with attached connection cable)通用参数
防护等级 / Protection classIII (SELV or PELV)通用参数
探头长度 / Probe length50/100/200/350/500 mm通用参数
重量 / Weight200 g max.通用参数

需要这款产品的报价与货期?

提供型号即可,我们将在 24 小时内回复正品渠道、价格与货期。