上海麒诺 QN TECHNOLOGY
SCHMIDT® Flow Sensor SS 20.250 流量传感器
Flow Sensor SS 20.250

SCHMIDT® Flow Sensor SS 20.250 流量传感器

SCHMIDT Technology询货期产地 德国

SCHMIDT® Flow Sensor SS 20.250 流量传感器,量程 0 ... 1 / 10 / 20 m/s; | Special measuring range inbetween 1 ... 20 m/s (steps o

产品概述

SCHMIDT® Flow Sensor SS 20.250 属于 SCHMIDT 实验室、制药与洁净室用流量传感器(Flow Sensors for Laboratory, Pharmaceutical and Clean Room Technology)产品线,量程 0 ... 1 / 10 / 20 m/s; | Special measuring range inbetween 1 ... 20 m/s (steps of 0.1 m/s);介质温度量程 -20 ... +70 °C;供电电压 24 V AC/DC ± 10 %;模拟输出 wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF | Voltage output: RL >= 500 ohmCurrent output: RL <= 500 ohmHysteresis: 50 ohm。我司经销 SCHMIDT Technology 原装全新正品,可提供选型支持、技术资料与稳定供货。

技术参数

测量量 / Measuring quantityStandard flow velocity wN based on standard conditions 1) | Temperature of medium TM技术参数
被测介质 / Measured mediumAir or nitrogen, other gases upon request技术参数
量程 / Measuring range wN0 ... 1 / 10 / 20 m/s; | Special measuring range inbetween 1 ... 20 m/s (steps of 0.1 m/s)技术参数
最低检出限 / Lower detection limit wN0.06 m/s技术参数
介质温度量程 / Measuring range TM-20 ... +70 °C技术参数
测量精度(标准) / Standard wN±(5 % of measured value + [0.4 % of fmr; min 0.02 m/s]) 2)测量精度
测量精度(高精度可选) / High precision (optional) wN±(3 % of measured value + [0.4 % of fmr; min 0.02 m/s]) 2)测量精度
响应时间 / Response time (t90) wN3 s (jump from 0 to 5 m/s in air)测量精度
温度梯度 / Temperature gradient wN< 2 K/min (at wN = 5 m/s in air)测量精度
TM (for wN > 1 m/s)±1 K (10 ... 30 °C); ±2 K (remaining measuring range)测量精度
Sensor / electronics-20 ... +70 °C工作温度
存储温度 / Storage temperature-30 ... +85 °C工作温度
湿度 / HumidityMeasuring mode: Non-condensing (< 95 % RH)通用参数
工作压力 / Operating pressureAtmospheric (700 ... 1,300 hPa)通用参数
显示 / DisplayDual-LED: | - Green: Status | - Red (flashing): Sensor defective通用参数
供电电压 / Supply voltage24 V AC/DC ± 10 %通用参数
电流消耗 / Current consumptionTypical < 60 mA, max. 100 mA通用参数
模拟输出 / Analog outputs | Type: Auto U / I)wN, TM | 0 ... 10 V / 4 ... 20 mA (switching of signal characteristic depends on RL) | -Voltage output (0 ... 10 V): RL >= 550 ohm (short-circuit protected) | - Current output (4 ... 20 mA): RL <= 500 ohm | - Change-over hysteresis: 50 ohm | - CL <= 10 nF | Voltage output: RL >= 500 ohmCurrent output: RL <= 500 ohmHysteresis: 50 ohm通用参数
电气连接 / Electrical connectionNon-detachable cable, 5 x 0,25 mm2 | Standard: Length 2 m or selectable (3 ... 100 m; steps of 1 m), with ferrules | Hygienic Design Option: 1.5 m, M12 plug (male, A-coded, 5 pole); | Additional content of delivery: Cable 10 m, M12 bushing (female, A-coded, 5 pole)通用参数
最大电缆长度 / Maximum cable lengthVoltage interface / current interface: 100 m | Voltage mode: Use AGND and RL >= 10 k (mass offset)通用参数
安装位置 / Mounting positionArbitrary通用参数
最小插入深度 / Minimum immersion depth58 mm (< 58 mm upon request)通用参数
防护等级 / Protection typeIP65通用参数
防护等级 / Protection classIII (SELV or PELV)通用参数
探头长度 / Probe length300/500 mm通用参数
重量 / Weight200 g max.通用参数
传感器管 / Sensor tubeStainless steel 1.4571材质
传感器头部 / Sensor headPBT (glass-fibre reinforced), stainless steel 1.4571材质
防护涂层 / Protective coating (optional)Polyurethan / parylene (coating not available for Hygienic Design version)材质
传感器电缆 / Sensor cableStandard: PUR, halogen-free | Hygienic Design Option: PP-EPDM, halogen-free材质

需要这款产品的报价与货期?

提供型号即可,我们将在 24 小时内回复正品渠道、价格与货期。