Products
Industrial Automation Components
Covering encoders, sensors, connectors, pneumatic components, instruments and other core categories — sourced direct from origin with genuine-product guarantee. Filter by category or brand to find your model; we provide quotation and lead time within 24 hours.
Browse products by brand
Open a brand directory page to see every model of that brand.
- Airtrol
- SCHMIDT Technology
- TECNA
- ROTEK
- AZ Pneumatica
- BANDELIN electronic GmbH & Co. KG
- Stromag GmbH
- Interroll Holding AG
- Maximator GmbH
- Fronius
- BEE
- Durgo
- Hengstler GmbH
- KTR Systems GmbH
- CKD
- Schaltbau
- Angst+Pfister
- Circutor
- Ahlborn
- Alfa Pompe
- Vaisala
- RAFI GmbH & Co. KG
- DIGISOUND-Electronic GmbH
- Conforti Oleodinamica S.r.l.
- Bailey & Mackey Ltd
- Time Electronics Ltd
- Aim and Thurlby Thandar Instruments
- Pico Technology Ltd.
- Telco Sensors A/S
- E+E Elektronik Ges.m.b.H.
- MadgeTech
- esitron electronic systems GmbH
- Wilcoxon
- Fenac
- Harting
- S+S Regeltechnik
Total 2554 products

SpaceGuard™ SG 10 Safety Light Curtain
SpaceGuard™ SG 10 is a Telco safety light curtain with a detection range of 1-10 meters, suitable for safety protection of mechanical equipment and automatic doors.

SpaceGuard™ SG 2 Safety Light Curtain
SpaceGuard™ SG 2 is a Telco safety light curtain with a detection range of 0-4 meters, suitable for safety protection of mechanical equipment and automatic doors.

SpaceGuard™ SG 1 Safety Light Curtain
SpaceGuard™ SG 1 is a Telco safety light curtain with a detection range of 0-4 meters, suitable for safety protection of mechanical equipment and automatic doors.

Photoelectric Amplifier Bus Programmable PABP 30 Remote Photoelectric System
The Photoelectric Amplifier Bus Programmable PABP 30 is a Telco remote optoelectronic system, featuring a detection performance of 0-47 meters in a correlative mode, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus Programmable PABP 20 Remote Photoelectric System
The Photoelectric Amplifier Bus Programmable PABP 20 is a Telco remote optoelectronic system, featuring a detection performance of 0-47 meters in a correlative mode, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus Programmable PABP 10 Remote Photoelectric System
The Photoelectric Amplifier Bus Programmable PABP 10 is a Telco remote optoelectronic system, featuring a detection performance of correlative type: 0-47 meters, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus Automatic PABA 30 Remote Photoelectric System
The Photoelectric Amplifier Bus Automatic PABA 30 is a Telco remote optoelectronic system, featuring a detection performance of 0-39 meters in a correlative mode, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus Automatic PABA 20 Remote Photoelectric System
The Photoelectric Amplifier Bus Automatic PABA 20 is a Telco remote optoelectronic system, featuring a detection performance of 0-39 meters in a correlative mode, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus Automatic PABA 10 Remote Photoelectric System
The Photoelectric Amplifier Bus Automatic PABA 10 is a Telco remote optoelectronic system, featuring a detection performance of 0-39 meters in a correlative mode, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus PAB 30 Remote Photoelectric System
The Photoelectric Amplifier Bus PAB 30 is a Telco remote optoelectronic system, featuring a detection performance of 0-47 meters for through-beam type and 0-2.6 meters for diffuse reflection type, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus PAB 20 Remote Photoelectric System
The Photoelectric Amplifier Bus PAB 20 is a Telco remote optoelectronic system, featuring a detection performance of 0-47 meters for the through-beam type and 0-2.6 meters for the diffuse reflection type. It is suitable for long-distance and multi-point object detection.

Photoelectric Amplifier Bus PAB 10 Remote Photoelectric System
The Photoelectric Amplifier Bus PAB 10 is a Telco remote optoelectronic system, featuring a detection performance of 0-70 meters for through-beam type and 0-4 meters for diffuse reflection type, suitable for long-distance and multi-point object detection.

Multiplexed Photoelectric Amplifier MPA 81 Remote Photoelectric System
The Multiplexed Photoelectric Amplifier MPA 81 is a Telco remote optoelectronic system, featuring a detection performance of 0-35 meters for the through-beam type and 0-2 meters for the diffuse reflection type. It is suitable for long-distance and multi-point object detection.

Multiplexed Photoelectric Amplifier MPA 41 Remote Photoelectric System
The Multiplexed Photoelectric Amplifier MPA 41 is a Telco remote optoelectronic system, featuring a detection performance of 0-35 meters for the through-beam type and 0-2 meters for the diffuse reflection type. It is suitable for long-distance and multi-point object detection.

Multiplexed Photoelectric Amplifier MPA 21 Remote Photoelectric System
The Multiplexed Photoelectric Amplifier MPA 21 is a Telco remote optoelectronic system, featuring a detection performance of 0-45 meters for through-beam detection and 0-3.5 meters for diffuse reflection detection, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier PA 15 Remote Photoelectric System
The Photoelectric Amplifier PA 15 is a Telco remote optoelectronic system, featuring a detection performance of 0-70 meters for through-beam type and 0-5 meters for diffuse reflection type, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier PA 11 Remote Photoelectric System
The Photoelectric Amplifier PA 11 is a Telco remote photoelectric system, featuring a detection performance of 0-70 meters for the through-beam type and 0-5 meters for the diffuse reflection type. It is suitable for long-distance and multi-point object detection.

Photoelectric Amplifier PA 10 Remote Photoelectric System
The Photoelectric Amplifier PA 10 is a Telco remote photoelectric system, featuring a detection performance of 0-60 meters for through-beam type and 0-4 meters for diffuse reflection type, suitable for long-distance and multi-point object detection.

Photoelectric Amplifier PA 01 Remote Photoelectric System
The Photoelectric Amplifier PA 01 is a Telco remote photoelectric system, featuring a detection performance of 0-45 meters for the through-beam type and 0-3.5 meters for the diffuse reflection type. It is suitable for long-distance and multi-point object detection.

Telco Remote Sensors - Remote Electro-Optical System
Telco Remote Sensors are remote electro-optical systems, featuring detection performance in the following modes: Correlation mode: dependent on amplifier (up to 70m); Diffuse reflection mode: dependent on amplifier (up to 5m), suitable for long-distance and multi-point object detection.

SpacePak™ SP 2000 Photoelectric Sensor
SpacePak™ SP 2000 is a Telco photoelectric sensor, with detection performance as follows: Correlation: 0-45 m; Diffuse reflection: 0-5 m; Retroreflection: 0-12 m; Polarized retroreflection: 0-10 m; Background suppression: 0-2 m. It is suitable for object presence and distance detection.

SpaceMaster™ SM 9000-IO Photoelectric Sensor
SpaceMaster™ SM 9000-IO is a Telco photoelectric sensor with a detection performance of correlative type: 0-70 m, suitable for object presence and distance detection.

SpaceMaster™ SM 9000 Photoelectric Sensor
SpaceMaster™ SM 9000 is a Telco photoelectric sensor with a detection performance of 0-70 meters in a correlative mode, suitable for object presence and distance detection.

SpaceMaster™ SM 8000 Photoelectric Sensor
The SpaceMaster™ SM 8000 is a Telco photoelectric sensor, featuring detection capabilities as follows: Correlation type: 0-20 m; Diffuse reflection type: 0-1 m; Retroreflective type: 0-3 m; Fiber optic type: Dependent on fibre optic, suitable for object presence and distance detection.

SpaceMaster™ SM 7000-IO Photoelectric Sensor
The SpaceMaster™ SM 7000-IO is a Telco photoelectric sensor, featuring detection capabilities as follows: Correlation type: 0-20 m; Diffuse reflection type: 0-1 m; Retroreflective type: 0.1-3 m; Fiber optic type: Dependent on the fiber optic, suitable for object presence and distance detection.

SpaceMaster™ SM 7000 Photoelectric Sensor
The SpaceMaster™ SM 7000 is a Telco photoelectric sensor, featuring detection capabilities as follows: Correlation: 0-20 m; Diffuse reflection: 0-1 m; Retroreflection: 0-3 m; Fiber optic: Varies depending on the fiber optic, suitable for object presence and distance detection.

SpaceMaster™ SM 6000 Photoelectric Sensor
The SpaceMaster™ SM 6000 is a Telco photoelectric sensor with a detection performance of 1-6 meters in a correlative mode, suitable for object presence and distance detection.

SpaceMaster™ SM 3000/CAT2 Photoelectric Sensor
The SpaceMaster™ SM 3000/CAT2 is a Telco photoelectric sensor with a detection performance of correlative type: 1-10 m, suitable for object presence and distance detection.

SpaceMaster™ SM 3000 Photoelectric Sensor
The SpaceMaster™ SM 3000 is a Telco photoelectric sensor with a detection performance of correlative type: 1-15 m, suitable for object presence and distance detection.

HMS60-500 Micro Differential Pressure Transmitter
The micro differential pressure transmitter utilizing a MEMS sensor boasts a measurement range of ±100 Pa to ±1000 Pa, an accuracy of ±1 % FS, a T63 response time of 0.5 seconds, and supports both 4-20 mA and RS485 outputs.

HTS201 Indoor Temperature and Humidity Sensor
Indoor temperature and humidity sensors for residential and commercial building automation offer two analog outputs or RS485 (Modbus RTU / BACnet MS/TP) and support tool-free snap-in installation.

HTP501 Digital Temperature and Humidity Probe (up to 120 ℃)
A digital temperature and humidity probe for industrial process control, with a temperature operating range of -40...120 ℃, a stainless steel casing rated at IP66, and RS485 Modbus RTU output.

EE451 Indoor and Outdoor Wall-Mounted Temperature Transmitter
Indoor and outdoor wall-mounted temperature transmitters are available, offering active outputs of 0-10 V and 4-20 mA, passive resistance output, or RS485 digital output with Modbus RTU / BACnet MS/TP.

EE471 Split-probe Temperature Transmitter
The temperature transmitter with a split probe is suitable for applications where installation space is limited or electronic components need to be protected. It provides analog output, RS485 Modbus RTU, and passive temperature sensor output.

EE431 Duct/Pipe Type Temperature Transmitter
Duct and pipe-mounted temperature transmitters offer 4-20 mA, 0-10 V active output or passive resistance output, with the option of RS485 (Modbus RTU / BACnet MS/TP).

EE046 OEM Sensing Module
E+E EE046 OEM sensor module; the attached PDF contains no extractable text, and the measurement parameters, range, accuracy, and output format must be verified against official E+E documentation.

EE850 Duct-type CO₂, Humidity, and Temperature Transmitter
Duct-mounted CO₂, relative humidity, and temperature transmitters, with a CO₂ measurement range of up to 10,000 ppm and a temperature operating range of -20...+60 ℃, are suitable for demand-controlled ventilation and building automation.

EE820 CO₂ Transmitter for Harsh Environments
For demanding environments such as incubators, livestock and poultry houses, and greenhouses, the CO₂ transmitter boasts a measurement range of up to 10,000 ppm, an IP54 enclosure with a dedicated filter, and supports analog output and Modbus/BACnet.

EE800 CO₂, Humidity, and Temperature Transmitter for HVAC Applications
A wall-mounted transmitter for HVAC and building control, capable of simultaneously measuring CO₂, temperature, and relative humidity, and calculating dew point, with a CO₂ measurement range of 0...2000 / 5000 ppm.

EE872 Transmitter
E+E EE872 transmitter; the attached PDF is a low-resolution scanned copy with no extractable text. Measurement parameters, range, output, and category must be verified against the official sample.

EE776 Compressed Air and Gas Pipeline Insertion Flowmeter DN50-DN300
The plug-in thermal mass flowmeter, suitable for pipelines ranging from DN50 to DN300, boasts a maximum measurement accuracy of 1.5% of the reading and a maximum working pressure of 16 bar. It features patented technology for one-way installation protection.

EE771 Compressed Air and Gas Flowmeter DN15-DN50
Compressed air and gas flowmeter for pipelines ranging from DN15 to DN50, with an accuracy of ±1.5% of reading, a measurement range ratio of 1:400, a built-in cumulative flow counter, and a maximum working pressure of 16 bar.

EE741 Compressed Air and Gas Pipeline Mass Flowmeter
The modular pipeline thermal mass flowmeter features a single transmitter unit that can be used for pipe diameters ranging from DN15 to DN50, with an accuracy of ±(3% of reading + 0.3% of full scale), and a maximum working pressure of 16 bar.

EE610 Micro Differential Pressure Transmitter
The micro-differential pressure transmitter, designed for critical applications such as clean rooms, hospitals, and laboratories, boasts a maximum measurement range of ±100 Pa and an accuracy of ±0.5 Pa across the entire range. It supports both analog output and Modbus RTU communication.

EE600 Differential Pressure Transmitter
A multi-range differential pressure transmitter for HVAC, building automation, and filter monitoring, with a measurement range spanning from 1,000 Pa to 10,000 Pa in both unidirectional and bidirectional modes, and an accuracy of ±0.5% FS.

EE680 Laminar Flow Wind Speed and Temperature Sensor
A GMP-compliant laminar flow velocity and temperature sensor, with a measurement range of 0...2 m/s and an accuracy of ±(0.5% of reading + 0.05 m/s), features a stainless steel casing with a laminar flow status LED indicator ring.

EE660 Low Wind Speed Transmitter
The low-speed transmitter designed for clean room laminar flow control and specialized ventilation applications utilizes the hot-film wind speed principle, achieving a measurement lower limit as low as 0.15 m/s. It supports analog output and Modbus RTU.

EE576 Low-Speed Wind Speed Measurement Probe
A compact low-wind speed probe designed for laminar flow control and filter monitoring, utilizing the hot-film wind speed principle, with a measurement range of 0...1 m/s or 0...2 m/s, and outputs of 0-5 V / 0-10 V.

EE75 Industrial High-Precision Wind Speed/Gas Flow Rate Transmitter
Industrial high-precision wind speed and temperature transmitters utilize the hot-film wind speed principle, with a wind speed measurement range of 0.06...40 m/s and a process temperature range of -40...120 ℃. They are capable of calculating volumetric flow.

EE355 OEM Dew Point Transmitter
Compact OEM dew point transmitter, with a dew point measurement range of -60...60 ℃ Td, an accuracy of ≤±2 ℃ Td, a stainless steel housing, 4-20 mA and Modbus RTU outputs, and a pressure resistance of 0...80 bar.

EE371 Compact Dew Point Transmitter
A compact dew point transmitter for compressed air and industrial drying equipment, with a dew point measurement range of -60...+60 ℃ Td, an accuracy of ±2 ℃ Td, and a maximum pressure resistance of 100 bar.

EE650 Transmitter
The E+E EE650 series transmitter supports the RS485 bus (up to 32 devices on one bus) and can be installed in conduit; the accompanying Chinese PDF contains only fragmented text, and the measurement parameters need to be verified.

EE160 Temperature and Humidity Transmitter for HVAC
The E+E EE160 series temperature and humidity transmitters are designed for temperature and humidity measurement in heating, ventilation, air conditioning, and building automation systems. The attached Chinese PDF for this entry contains no extractable text, and the technical specifications require verification.

EE165 Temperature and Humidity Transmitter for the Pharmaceutical Industry
The temperature and humidity transmitter designed for the pharmaceutical industry utilizes the HCT01 sensing element with patented E+E coating, achieving a humidity accuracy of ±2 %RH. It is available in wall-mounted and duct-mounted versions, with a protection level of IP65 / NEMA 4.

EE072 OEM Temperature and Humidity Transmitter
The E+E EE07x series OEM temperature and humidity transmitters are designed for temperature and humidity measurement in equipment integration. The attached PDF to this entry is a scanned copy with no extractable text. Technical parameters should be verified against official documentation.

EE071 OEM Temperature and Humidity Transmitter with Modbus Interface
A digital OEM temperature and humidity transmitter specifically designed for bus applications, featuring an RS485 interface that supports the Modbus RTU protocol and a typical current consumption of just 0.4 mA, making it ideal for battery-powered devices.

EE310 High-end Temperature and Humidity Transmitter for Demanding Process Control
Equipped with a 3.5-inch TFT color display and data recording capabilities, this high-end temperature and humidity transmitter features a split probe that can operate at temperatures up to 180℃ and a pressure-resistant connector capable of withstanding pressures up to 20 bar.

EE220 Replaceable Digital Probe Temperature and Humidity Transmitter
The temperature and humidity transmitter equipped with a digital pluggable measurement probe stores calibration data within the probe. Interchanging probes does not affect the measurement results, making it suitable for use in cleanrooms, pharmaceutical, electronics, and other industries.

EE212 Temperature and Humidity Transmitter with Replaceable Measurement Module
The temperature and humidity transmitter, featuring a field-replaceable calibration measurement module, provides two analog outputs and supports BACnet MS/TP or Modbus RTU interfaces, making it ideal for climate control in polluted or erosive environments.

EE210 Temperature and Humidity Transmitter for Harsh Environment Control
For temperature and humidity transmitters designed for demanding environmental control, in addition to measuring relative humidity and temperature, they can calculate dew point, absolute humidity, and mixture ratio. These transmitters are available in wall-mounted, duct-mounted, split probe, and outdoor models, with a protection level of IP65 / NEMA 4X.
