上海麒诺 QN TECHNOLOGY

Products

Industrial Automation Components

Covering encoders, sensors, connectors, pneumatic components, instruments and other core categories — sourced direct from origin with genuine-product guarantee. Filter by category or brand to find your model; we provide quotation and lead time within 24 hours.

Total 2554 products

Y-type Filter YS
YSLead Time on Inquiry

Y-type Filter YS

CKD

Remove foreign objects from the water piping to protect the equipment. Add to Favorites

Attachment(s)
Water pressure reducing valve WR
WRLead Time on Inquiry

Water pressure reducing valve WR

CKD

Pursue a compact water pressure reducing valve with ease of use. The knob shape facilitates pressure adjustment operations, and a filter screen is standard. Model generation system Add to Favorites

Water-related components
Water Integration Unit WXU
WXULead Time on Inquiry

Water Integration Unit WXU

CKD

An integrated unit featuring a flow sensor and valve for the cooling water circulation loop has been realized. This not only significantly reduces the cumbersome piping design and labor hours required for piping operations in the water circuit, but also reduces the occupied space by 80%, achieving space-saving for the system. Physicochemical analysis equipment Model generation system Add to favorites

Water-related components
Manual pinch valve HPV
HPVLead Time on Inquiry

Manual pinch valve HPV

CKD

[Discontinued Product] Rubber-sleeve type pinch valve for manual opening and closing operations. Capable of controlling various fluids such as gas, water, colloids, and powders. Add to Favorites

Pipe clamp valve
Direct Air Pressure Automatic Tube Clamp Valve NPV2
NPV2Lead Time on Inquiry

Direct Air Pressure Automatic Tube Clamp Valve NPV2

CKD

A rubber bushing-style pinch valve that utilizes compressed air for opening and closing operations. It can control various fluids such as gas, water, colloids, and powders. Add to Favorites

Pipe clamp valve
Electromagnetic pinch valve (precision pinch valve) HYN
HYNLead Time on Inquiry

Electromagnetic pinch valve (precision pinch valve) HYN

CKD

Utilize the pinch valve for coil opening and closing piping. Adopt a structure where only the piping comes into contact with the liquid, making it most suitable for controlling pure water, physiological saline, reagents, cleaning agents, etc. Biochemical analysis equipment, physicochemical analysis equipment, endoscope-related devices, model generation system, add to favorites

Pipe clamp valve
Pneumatically Controlled Precision Tube Clamp Valve HYA
HYA(管夹阀)Lead Time on Inquiry

Pneumatically Controlled Precision Tube Clamp Valve HYA

CKD

Precision pinch valve utilizing pneumatic technology. Ideal for sterile environments such as single-piston processes in pharmaceutical manufacturing. Due to the absence of coils, it does not generate heat when energized, thus avoiding thermal impact on the control fluid and the surrounding environment. Biochemical analysis equipment Endoscope-related devices Physicochemical analysis equipment Model generation system Add to Favorites

Pipe clamp valve
Wear-resistant Diaphragm Valve Flow Control Type [Exclusively for Sale in Japan] SWD-T
SWD-TLead Time on Inquiry

Wear-resistant Diaphragm Valve Flow Control Type [Exclusively for Sale in Japan] SWD-T

CKD

A sanitary flow control valve with high cleanability and liquid displacement capability. It achieves the flow control required for pharmaceutical manufacturing processes such as sterile infusion, as well as for the manufacturing of biological and high-performance foods. It can memorize and reproduce fluid control techniques. This series facilitates the automation of manual valve flow adjustment. Refined water production, sterilization (autoclave), sterilization device, model generation system, add to favorites

Sanitation system
Stop-type diaphragm valve [exclusively available in Japan] SPD
SPDLead Time on Inquiry

Stop-type diaphragm valve [exclusively available in Japan] SPD

CKD

A diaphragm valve that prioritizes hygiene and ease of use. By applying technologies developed in semiconductor manufacturing processes to pharmaceuticals and food, it achieves high cleanliness, durability, and maintainability. It is most suitable for manufacturing processes in pharmaceuticals and food. Refined water production Model generation system Add to Favorites

Sanitation system
Wear-resistant Diaphragm Valve SWD・MWD
SWD・MWDLead Time on Inquiry

Wear-resistant Diaphragm Valve SWD・MWD

CKD

A sanitary valve with high cleanability and liquid displacement performance. Ideal for pharmaceutical manufacturing processes such as infusion that require sterility. Refined water production Model generation system Add to Favorites

Sanitation system
Medium-pressure gas shield valve (quick-opening type) VNM
VNMLead Time on Inquiry

Medium-pressure gas shield valve (quick-opening type) VNM

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Quick opening shielding valve suitable for medium pressure (0.3MPa) gas. Cold and warm water machine metal equipment hydrogen refining device model generation system added to favorites

Gas combustion system
Medium-pressure gas combination valve [Exclusively for sale in Japan] GRV
GRVLead Time on Inquiry

Medium-pressure gas combination valve [Exclusively for sale in Japan] GRV

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Integrating the medium pressure (0.3Mpa) regulator with the secondary side shut-off valve significantly reduces pressure loss. Compared to traditional products (TAC-25).

Gas combustion system
Intermediate Pressure Gas Combination Valve GHV
GHVLead Time on Inquiry

Intermediate Pressure Gas Combination Valve GHV

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Combination type shielding valve suitable for gases with intermediate pressure (up to 50kPa). Integrated with 2 solenoid valves, supporting dual shut-off to ensure safety. There is also a built-in speed controller available.

Gas combustion system
Flow Switching Solenoid Valve (Quick-Opening Type) VNA-R and VNA-RH
VNA-R・VNA-RHLead Time on Inquiry

Flow Switching Solenoid Valve (Quick-Opening Type) VNA-R and VNA-RH

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Switch between low flow and high flow electromagnetic flow switching valves. By switching between strong and weak firepower.

Gas combustion system
Electromagnetic relief valve VNR
VNRLead Time on Inquiry

Electromagnetic relief valve VNR

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Gas overflow pipeline for industrial combustion equipment. Close when powered on, open the valve when powered off to release gas from the piping to ensure safety. Cold and warm water machine metal equipment hydrogen refining device model generation system added to favorites

Gas combustion system
Gas Shutoff Valve (Slow-Opening Type) VLA
VLALead Time on Inquiry

Gas Shutoff Valve (Slow-Opening Type) VLA

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Suitable for slow opening gas shielding valves with intermediate pressure. Available in various calibers ranging from Rp1/2 to 2 1/2. Cold and warm water machine metal equipment hydrogen refining device model generation system added to favorites

Gas combustion system
Gas Shielding Valve (Quick-Opening Type) VNA
VNALead Time on Inquiry

Gas Shielding Valve (Quick-Opening Type) VNA

CKD

​1​Add a selection option for adding hydrogen to the fluid to ensure its use in hydrogen environments. To make hydrogen pipelines easier to identify, a nameplate in the dedicated color for hydrogen (red) is attached to the valve cover. It is suitable for quick-opening gas shutoff valves with intermediate pressure. Available in multiple sizes ranging from Rp1/2 to 2 1/2. Chiller Metal equipment Hydrogen purification unit Model generation system Add to Favorites

Gas combustion system
Gas Shield Valve (Quick-Opening Type) DSG
DSGLead Time on Inquiry

Gas Shield Valve (Quick-Opening Type) DSG

CKD

【 NEW 】 Add hydrogen corresponding selection options in the fluid to ensure its use in hydrogen. In order to make the hydrogen pipeline easier to identify, a hydrogen specific color (red) nameplate is affixed to the valve cover. Gas shielding valve with caliber (Rp1/2, Rp3/4, Rp1) and low pressure (5kPa) specifications. There is also a 2-connected type for double blocking. Cold and warm water machine metal equipment hydrogen refining device model generation system added to favorites

Gas combustion system
Direct-acting 2-way solenoid valve (hydrogen compatible) [Exclusively for sale in Japan] FFB-H2
FFB-H2Lead Time on Inquiry

Direct-acting 2-way solenoid valve (hydrogen compatible) [Exclusively for sale in Japan] FFB-H2

CKD

Maintain high reliability and ease of use. This product series can accommodate the fluids required by the new generation of combustion devices. ※ When using hydrogen outside of the gas system, please consult our sales office. Chiller/Heater Add to Favorites

Gas combustion system
Pneumatically-controlled 2-way cylinder valve (hydrogen compatible) [Exclusively available in Japan] SAB-H2
SAB-H2Lead Time on Inquiry

Pneumatically-controlled 2-way cylinder valve (hydrogen compatible) [Exclusively available in Japan] SAB-H2

CKD

[Compatible with Next-Generation Combustion Systems] One model can accommodate hydrogen, city gas, LPG, and nitrogen. ※ When using hydrogen outside the gas system, please consult our sales office. Model Generation System Add to Favorites

Gas combustion system
Operational BOX-type multi-connected solenoid valve (2-way solenoid valve for pulse jet valve control) - PJVB
PJVBLead Time on Inquiry

Operational BOX-type multi-connected solenoid valve (2-way solenoid valve for pulse jet valve control) - PJVB

CKD

The pneumatically controlled dust collection valve PD series operates with a 2-way solenoid valve. It is of a box-type design, capable of housing up to 12 solenoid valves. Model generation system Add to Favorites

Dust collection components
Timing control component (pulse jet controller) OMC2
OMC2Lead Time on Inquiry

Timing control component (pulse jet controller) OMC2

CKD

A controller for managing multiple dust collector valves used in dust collectors. Model generation system. Add to Favorites

Dust collection components
Explosion-proof pilot-operated 2-way solenoid valve PDVE4
PDVE4Lead Time on Inquiry

Explosion-proof pilot-operated 2-way solenoid valve PDVE4

CKD

The pulsating jet valve, which is most suitable for removing dust from bag-type dust collection devices, features a d2G4 flameproof structure and can be used in explosion-proof environments. Model generation system Add to Favorites

Dust collection components
Pulse jet valve PD2, PDV2, PD3, PDV3
PD2・PDV2・PD3・PDV3Lead Time on Inquiry

Pulse jet valve PD2, PDV2, PD3, PDV3

CKD

The most suitable pulsating jet valve for removing dust from bag-type dust collection devices. Model generation system. Add to Favorites

Dust collection components
Rain Sensor RS-6
RS-6Lead Time on Inquiry

Rain Sensor RS-6

CKD

Rain sensor compatible with watering controller. Cancels watering when rainfall of 6mm or more is detected. Model generation system. Add to favorites

Automatic sprinkler control component
Automatic Water Sprinkler Controller RSC
RSCLead Time on Inquiry

Automatic Water Sprinkler Controller RSC

CKD

A controller for electromagnetic valves used in water sprinkling. Suitable for various applications ranging from facility horticulture to golf courses and facility greening. Compatible with power sources such as solar-powered, commercial power supplies, and dry batteries. Model generation system. Add to Favorites

Automatic sprinkler control component
Solenoid valve for automatic watering, RSV
RSVLead Time on Inquiry

Solenoid valve for automatic watering, RSV

CKD

An automatic watering solenoid valve with a metal valve body, suitable for various applications ranging from facility horticulture to golf courses and facility greening. Model generation system. Add to Favorites

Automatic sprinkler control component
Resin-made solenoid valve for automatic watering GSV
GSVLead Time on Inquiry

Resin-made solenoid valve for automatic watering GSV

CKD

Resin-made solenoid valves suitable for applications ranging from greening irrigation to the control of liquid fertilizers and nutrient solutions for agricultural use. Model generation system. Add to Favorites

Automatic sprinkler control component
Resin-made solenoid valve for automatic watering GSV2
GSV2Lead Time on Inquiry

Resin-made solenoid valve for automatic watering GSV2

CKD

Resin-made solenoid valves suitable for applications ranging from greening watering to the control of liquid fertilizers and nutrient solutions for agriculture. Easy-to-use union connectors allow for piping construction without the need for tools. Model generation system. Add to Favorites

Automatic sprinkler control component
Metal-free 2-way solenoid valve MJB3
MJB3Lead Time on Inquiry

Metal-free 2-way solenoid valve MJB3

CKD

Tubing connection type. Suitable for water, pure water, and chemical liquids. Supports fluid temperatures up to 90°C. Biochemical analysis equipment, dialysis monitoring devices, dental medical equipment. Add to Favorites

Life Science Components
Metal-free 2-way solenoid valve MKB3
MKB3Lead Time on Inquiry

Metal-free 2-way solenoid valve MKB3

CKD

Ideal for medical analysis devices. A thin and compact metal-free 2-way solenoid valve. Features a quick-installation structure for easy maintenance. Biochemical analysis equipment Dental medical equipment Model generation system Add to Favorites

Life Science Components
Metal-free 2-way/3-way solenoid valve MR16
MR16Lead Time on Inquiry

Metal-free 2-way/3-way solenoid valve MR16

CKD

Indicator-equipped lever diaphragm valve. The control valve most suitable for enhancing the efficiency of medical analysis devices. Biochemical analysis equipment, dialysis monitoring devices, dental medical equipment, model generation systems. Add to Favorites

Life Science Components
Metal-free Mini 2-way/3-way Solenoid Valve MR10R
MR10RLead Time on Inquiry

Metal-free Mini 2-way/3-way Solenoid Valve MR10R

CKD

The parts that come into contact with the liquid are made of resin or rubber materials, without any metal content. This is a metal-free 2-way and 3-way solenoid valve for small chemical liquids that meets European standards. Biochemical analysis equipment, dialysis monitoring devices, dental medical equipment, and model generation systems can be added to the favorites list

Life Science Components
Pilot-operated 2-way solenoid valve for compressed air - EXA and GEXA
EXA・GEXA(生命科学元件)Lead Time on Inquiry

Pilot-operated 2-way solenoid valve for compressed air - EXA and GEXA

CKD

Small pilot-operated solenoid valve for compressed air control. Ideal for air blowing applications, it helps enhance the environmental performance of devices and systems. Dental medical equipment, fixture-related, model generation system, add to favorites

Life Science Components
Direct-acting 2-way and 3-way solenoid valves USB and USG
USB・USG(生命科学元件)Lead Time on Inquiry

Direct-acting 2-way and 3-way solenoid valves USB and USG

CKD

Supporting a wide range of fluids, it is most suitable for small direct-acting solenoid valves mounted on devices. Additionally, it comes with resin valve bodies and connector-integrated models, making it suitable for various applications. Model generation system Add to Favorites

Life Science Components
SELEX Valve 3PA/B and M3PA/B
3PA/B・M3PA/BLead Time on Inquiry

SELEX Valve 3PA/B and M3PA/B

CKD

This is a direct-acting and pressurized 3-way valve suitable for use in applications ranging from 0.7 MPa to low vacuum. It facilitates the construction of systems for low pressure and vacuum purposes. [Applicable cylinder diameter: Φ16 to Φ40] Oxygen concentrator Respirator/anesthesia machine Model generation system Add to favorites

Life Science Components
Direct-acting 3-way valve 3QR, 3QB, 3QE, 3QZ
3QR・3QB・3QE・3QZLead Time on Inquiry

Direct-acting 3-way valve 3QR, 3QB, 3QE, 3QZ

CKD

It can handle various applications of small 3-way valves (such as pneumatic control valves, cylinder drives, adsorption conveyors, and air blowing). There are dedicated positive pressure 3QE and 3QZ series, positive and negative pressure 3QB series, and high-flow positive and negative pressure 3QR series. [Applicable cylinder diameters: Φ6 to Φ20] Semiconductor manufacturing process (pre-process) Semiconductor manufacturing process (post-process) Oxygen concentrator Dialysis monitoring device Dental medical equipment Model generation system Add to favorites

Life Science Components
Proportional solenoid valve [special specification product] A2-6500
A2-6500Lead Time on Inquiry

Proportional solenoid valve [special specification product] A2-6500

CKD

Directly proportional to the operating current value, "multi-stage fluid control" and "appropriate control" can be achieved through non-stage control of gas flow. It plays a role in the proportion control of air and oxygen in artificial respirators and other devices. Oxygen concentrator, dental medical equipment, ventilator/anesthesia machine. Add to Favorites

Life Science Components
Pneumatically-controlled Precision Tube Clamp Valve HYA
HYALead Time on Inquiry

Pneumatically-controlled Precision Tube Clamp Valve HYA

CKD

Precision pinch valve utilizing pneumatic technology. Ideal for sterile environments such as single-piston processes in pharmaceutical manufacturing. Due to the absence of coils, it does not generate heat when energized, thus avoiding thermal impact on the control fluid and the surrounding environment. Biochemical analysis equipment Endoscope-related devices Physicochemical analysis equipment Model generation system Add to favorites

Life Science Components
The International Integrated Explosion-Proof Policy (ExdⅡBT2) applies to solenoid valves (explosion-proof multi-purpose fluid valves) EX2
EX2Lead Time on Inquiry

The International Integrated Explosion-Proof Policy (ExdⅡBT2) applies to solenoid valves (explosion-proof multi-purpose fluid valves) EX2

CKD

Explosion-proof solenoid valve supporting multiple fluids. Products compliant with the International Standard (IEC) for integrated explosion protection have been certified as ExdⅡBT2, allowing use in explosion-proof areas. Equipped with a Class 180 (H) heat-resistant coil, it can be used for steam. Model Generation System Add to Favorites

Explosion-proof 2-way and 3-way solenoid valve
The International Integrated Explosion-Proof Policy (ExdⅡBT4) applies to solenoid valves (explosion-proof multi-purpose fluid valves) EX4
EX4Lead Time on Inquiry

The International Integrated Explosion-Proof Policy (ExdⅡBT4) applies to solenoid valves (explosion-proof multi-purpose fluid valves) EX4

CKD

Explosion-proof solenoid valves supporting multiple fluids. Products compliant with the International Standard (IEC) for integrated explosion protection have been certified to ExdⅡBT4 and are suitable for use in explosion-proof areas. Model Generation System Add to Favorites

Explosion-proof 2-way and 3-way solenoid valve
d2G2 Explosion-proof 2-way Solenoid Valve (Explosion-proof Multi-purpose Fluid Valve) E2
E2Lead Time on Inquiry

d2G2 Explosion-proof 2-way Solenoid Valve (Explosion-proof Multi-purpose Fluid Valve) E2

CKD

Explosion-proof solenoid valve supporting multiple fluids. Flameproof structure compliant with d2G2 standard, suitable for use in explosion-proof areas. Equipped with Class 180 (H) heat-resistant coil, suitable for steam applications. In addition to the previous Japanese certification (TIIS), it can also comply with China's GB specification certification (NEPSI) and China Compulsory Certification (CCC). Model generation system Add to Favorites

Explosion-proof 2-way and 3-way solenoid valve
d2G4 Explosion-proof 2-way/3-way Solenoid Valve (Explosion-proof Multi-purpose Fluid Valve) E4
E4Lead Time on Inquiry

d2G4 Explosion-proof 2-way/3-way Solenoid Valve (Explosion-proof Multi-purpose Fluid Valve) E4

CKD

Explosion-proof solenoid valves supporting multiple fluids. Flameproof structure compliant with d2G4 standards, suitable for use in explosion-proof areas. In addition to the previous Japanese certification (TIIS), it can also comply with China's GB specification certification (NEPSI) and China Compulsory Certification (CCC). Model generation system Add to Favorites

Explosion-proof 2-way and 3-way solenoid valve
Direct-acting 2-way and 3-way solenoid valves for dry air (special valves) - FGB, FGG, GFGB, GFGG
FGB・FGG・GFGB・GFGGLead Time on Inquiry

Direct-acting 2-way and 3-way solenoid valves for dry air (special valves) - FGB, FGG, GFGB, GFGG

CKD

[Discontinued Product] Replacement Product: FFB and FFG Series High-durability direct-acting solenoid valves suitable for applications ranging from dry air with an atmospheric dew point of -60°C to inert gases such as nitrogen. Featuring a thin design, they save space. Special Applications, Transportation Add to Favorites

Solenoid valve for dry air
Pilot snap-action solenoid valve for dry air (multi-purpose fluid valve) ADK11-Z
ADK11-ZLead Time on Inquiry

Pilot snap-action solenoid valve for dry air (multi-purpose fluid valve) ADK11-Z

CKD

Suitable for high-endurance diaphragm solenoid valves ranging from dry air with an atmospheric dew point of -60°C to inert gases such as nitrogen. Model generation system. Add to Favorites

Solenoid valve for dry air
Direct-acting 2-way and 3-way solenoid valves for dry air (multi-purpose fluid valves) - AB, GAB, AG, GAG-Z
AB・GAB・AG・GAG-ZLead Time on Inquiry

Direct-acting 2-way and 3-way solenoid valves for dry air (multi-purpose fluid valves) - AB, GAB, AG, GAG-Z

CKD

Suitable for high-endurance direct-acting solenoid valves ranging from dry air with an atmospheric dew point of -60°C to inert gases such as nitrogen. Model generation system Add to Favorites

Solenoid valve for dry air
Pneumatically controlled 2-way and 3-way valves (coolant valves) CV and CVS
CV・CVSLead Time on Inquiry

Pneumatically controlled 2-way and 3-way valves (coolant valves) CV and CVS

CKD

[Discontinued Products] Replacement Products: 2-way Valves: CVE, CVSE, GCVE, GCVSE Series 3-way Valves: CVE3, CVSE3 Series, CVE3, CVSE3 Series Add to Favorites

Coolant components
Pressure switch for coolant, CPE and CPD
CPE・CPDLead Time on Inquiry

Pressure switch for coolant, CPE and CPD

CKD

Pressure switch for supporting coolant. With a protection level equivalent to IP65, it is most suitable for managing coolant in machine tools. Coolant Control Add to Favorites

Coolant components
Check valve (for liquids) CCH
CCHLead Time on Inquiry

Check valve (for liquids) CCH

CKD

Adopting a flow path structure with strong resistance to foreign matter, this check valve is most suitable for use with cooling fluid. The pipe diameters available include Rc3/8, 1/2, and 3/4. Coolant Control Model Generation System Add to Favorites

Coolant components
Low-pressure 3-way valve (coolant valve) CV3E・CVS3E
CV3E・CVS3ELead Time on Inquiry

Low-pressure 3-way valve (coolant valve) CV3E・CVS3E

CKD

Dedicated to cooling fluid control for machine tools, this 3-way pneumatic control valve boasts strong resistance to foreign matter. [Maximum operating pressure: 0.3 MPa] [Pipe diameter: Rc3/4, 1] Cooling fluid control Model generation system Add to favorites

Coolant components
Medium and High Pressure Pneumatically Operated 3-Way Valve (Coolant Valve) CVE3・CVSE3
CVE3・CVSE3Lead Time on Inquiry

Medium and High Pressure Pneumatically Operated 3-Way Valve (Coolant Valve) CVE3・CVSE3

CKD

Dedicated to the control of coolant for machine tools, this 3-way pneumatic control valve boasts strong resistance to foreign matter. The pipe diameter ranges from Rc3/8 to 1, and it is equipped with both medium-pressure (3.5MPa) and high-pressure (7.0MPa) specifications. Coolant Control Model Generation System Add to Favorites

Coolant components
Pneumatically-controlled 2-way valve (coolant valve) CVE2, CVSE2, GCVE2, GCVSE2
CVE2・CVSE2・GCVE2・GCVSE2Lead Time on Inquiry

Pneumatically-controlled 2-way valve (coolant valve) CVE2, CVSE2, GCVE2, GCVSE2

CKD

Dedicated to the control of machine tool coolant, this air control valve boasts strong resistance to foreign matter. It is available in various pipe diameters and pressure specifications (up to 7.0 MPa), offering a diverse range of types such as solenoid valve-mounted and integrated models to optimize coolant control. Coolant Control Model Generation System Add to Favorites

Coolant components
Steam pneumatic ball valve 2-way valve (compact rotary valve) CSB・CSBF
CSB・CSBFLead Time on Inquiry

Steam pneumatic ball valve 2-way valve (compact rotary valve) CSB・CSBF

CKD

Pneumatically-controlled 2-way valve for steam. Utilizing pneumatic power for robust opening and closing, it exhibits strong resistance to foreign matter, low pressure loss, and is capable of controlling high flow rates. It supports fluid temperatures up to 164°C. Model generation system. Add to Favorites

ball valve
Proportional control electric ball valve 2-3 way valve MXBC2・MXGC2
MXBC2・MXGC2Lead Time on Inquiry

Proportional control electric ball valve 2-3 way valve MXBC2・MXGC2

CKD

Proportional control electric ball valve. It can adjust the opening proportionally according to the input signal, suitable for various processes such as temperature control. Model generation system. Add to favorites

ball valve
Electric ball valve for steam, 2-way valve, MSB
MSBLead Time on Inquiry

Electric ball valve for steam, 2-way valve, MSB

CKD

Low pressure loss, electrically operated ball valve for steam service with controllable high flow. Model generation system. Add to Favorites

ball valve
Micro electric ball valve 2-3 way valve MHB4・MHG4
MHB4・MHG4Lead Time on Inquiry

Micro electric ball valve 2-3 way valve MHB4・MHG4

CKD

Equipped with micro electric ball valves in various pipe diameters ranging from Rc3/8 to 3/4. Small and lightweight, it is ideal for device installation. Model generation system Add to Favorites

ball valve
Electric ball valve 2-way and 3-way valves MXB1 and MXG1
MXB1・MXG1Lead Time on Inquiry

Electric ball valve 2-way and 3-way valves MXB1 and MXG1

CKD

An electric ball valve with low pressure loss and minimal water hammer phenomenon. It offers a wide range of pipe diameters and options, enabling control over various fluids, from general fluids to pure water. Model generation system Add to Favorites

ball valve
Pneumatically Controlled Ball Valve 2-3 Way Valve (Compact Rotary Valve) CHB・CHG
CHB・CHGLead Time on Inquiry

Pneumatically Controlled Ball Valve 2-3 Way Valve (Compact Rotary Valve) CHB・CHG

CKD

Pneumatically-controlled ball valve. Utilizing pneumatic power to achieve robust opening and closing, it exhibits strong resistance to foreign matter, low pressure loss, and enables high-flow control. It also comes in a solenoid valve-mounted version. Model generation system Add to Favorites

ball valve
Diaphragm Cylinder Valve LAD
LADLead Time on Inquiry

Diaphragm Cylinder Valve LAD

CKD

Suitable for clean-type pneumatic control valves with pipe diameters ranging from Rc3/8 to 1, where the flow path and drive section are isolated. Valve body and diaphragm materials can be selected to accommodate various fluids. Model generation system Add to Favorites

Pneumatic control valve (cylinder valve)
Diaphragm Cylinder Valve NAD・GNAD
NAD・GNADLead Time on Inquiry

Diaphragm Cylinder Valve NAD・GNAD

CKD

It is a clean, compact pneumatic control valve with completely isolated flow path and sliding parts. It supports integrated valves, saving space in devices and systems. Model generation system Add to Favorites

Pneumatic control valve (cylinder valve)